Crystallized Hopper Dryer / PET Crystallizer
Crystallized Hopper Dryer
PET Crystallizer
Our PET / PLA Crystallizer is a closed-loop heating system continuously to re-crystallize PET amorphous resin and covert it into crystalline state.
FEATURES
-
The crystallized hopper dryer is designed with a unique mixer inside the stainless insulated hopper.The unique mixer stirs the resin simultaneously while the unit is drying.To crystallize,it increases the I.V. value and speeds up the crystallization. To Dry the mixer dries evenly and shortens the drying time.
-
YANN BANG Crystallized Hopper Dryer is the best choice for PET users.
1. SAVE COST. With YANN BANG's patented drying technology,the crystallized hopper dryer mixes the resin evenly while drying and shortens the drying time.
2. PREVENT BRIDGE MAKING. When drying oily,sticky,abnormal shaped resin,it is easy to have the bridge making.To use the crystallized hopper dryer can prevent the bridge making effectively.
3. NUMEROUS MIXERS AVAILABLE. Different kinds of unique mixers to suit for your special needs.
SPECIFICATION

REMARKS
-
The reference values may be changed by the resin difference, environment difference, and others.
-
Specific gravity (Granular) :0.77
-
Total Power=Heater+Mixer Motor
-
We reserve the right to change the specification without prior notice.
STANDARD ACCESSORIES
-
Intelligent P.I.D. digital temperature controller
-
Clean door protector
-
Motor overload protector
-
Overheat preventer
OPTION
-
Multi-Function Temperature Controller
-
Motor (customized)
-
CHD-F: continuous function
-
Mixer: S type for standard, T type for bridge-break, A type for advanced
FAQ
Hopper Dryer
-
Check if there is any air leakage of unit.
-
Check if Fan motor is running in correct direction and if the Iron net is stocked.
-
Check if Heater and thermocouple is ok, and use Device to get Electrical current value.
-
Check if there is resin gathering around Right side of unit and inside dust collector chamber.
-
Check if Contactors, temperature controllers, EGO, and Thermocouple is OK.
-
-
1-1 Check Air volume of Fan Motor from its 90 degrees Outlet port.
1-2 Check if Electrical current and resistance of Heater is Normal.
1-3 Check if Both Temperature Indicators, Up and down, share Same value. And also check if Frequency of ON/OFF is Normal.
1-4 Check if there is Spreader Cone inside Drying Chamber of unit. -
Hopper Dryer is NOT Fulfilled with Material.
-
Check if there is any air leakage of the unit.
-
If possible, please try another brand of Material to check if our unit is working OK.
4-1 Setting temperature is not High enough, please increase it. ( For example, ABS sets at 80℃, try to increase to 85℃, 90℃, and so on. and Ensure Material is not gathering together cause of High Temperature.)
4-2 Drying time may be Not long enough, please increase drying time.
4-3 Special Material, pellet is tiny and dense, we would suggest to have a special device to ensure material is dried completely and loading in orders.
-
-
Check if Capacitors and Wiring are Burned.
-
Check if Voltage of Factory is Normal and Stable. This is because Differences between 3 Phases of Voltage would also damage the unit.
-
Check if Wirings of Fan Motor, Heater, and inside control box are in good condition, not damaged or peeled, because this would lead Electric to steel cover to cause Electric leakage.
Set Temperature to do Automatic calculation or Adjust PID value manually.
You would see ① Indicator of SB is ON and ② Displayed FFF or - -
Positive and Negative Pole of Thermocouple are not connected correctly.
Positive Pole connects RED wires.
Negative Pole connects BLUE wires.
Check if Power cable is damaged or broken.
Motor overload protector triggered.
-
Check if Switch of Fan Motor is connected correctly.
-
Check if lack phase of Motor. Lack phase of Motor would lead Motor is Not Running although switch of Fan Motor is ON. And Heating is ON to lead smoke.
-
-
EGO protector triggered.
-
OP protector triggered.
-
Replace with New lamps.
-
Dehumidifying Dryer
-
Check both of Dehumidifying dryer and Hopper dryer if they are suitable.
-
Check both of DHM (DHC) and HD if they have air leakage.
-
Check if the raw material contains oil or added.
-
The function of desiccant and honey comb rotor is unstable for dehumidify or regeneration.
-
Evaporator blocked, heating element fault or regeneration temperature is too low.
-
Check the spares of PU-TR, timer 60M x 12S, PU-NC, SENSOR, compressor air source…etc. Check it step by step to solve the failure.
It may EGO error or breakdown. Thermal bar poor assembling and poor contact causes overheat of temperature controller and SSR failure.
To replace temperature controller, auto computing and adjust PID.
Check cooling water, filter, evaporator and cooler.