top of page

Multi Mold Temperature Controller

Multi Mold Temperature Controller (YMWP)

Our multi functions mold temperature controller combines a chiller and a mold temperature controller to one. No need to wait or switch either your chiller or your mold temperature controller to cool down or heat up the required temperature.

FEATURES

  • YMWP-I type upgrade functions in compact size, maximum degree up to 180℃ for more applications.

  • Heat Up & Cool Down Your Mold Without Waiting!

  • YMWP combines a chiller and a mold temperature controller to one. No need to wait or switch either your chiller or your mold temperature controller to cool down or heat up the required temperature.

  • YMWP is different to other generic chillers or mold temperature controllers which can supply cooling water and hot water for your mold at the same time in steady and good condition. Save your energy cost and space.

  1. Cool down quickly from 35°C to 10°C in minutes.

  2. Use the latest European, American or Japanese compressor and pump.

  3. High-efficient transmission function can save up to 25% energy.

  4. Excellent stability.

  5. Save time to preheat or cool down your mold’s temperature degree.

  6. Completed safety protection to lengthen the machine life time.

  7. Save space and cost. Supply cooling water and hot water at the same time by the 2-in-1 design.

SPECIFICATION

Multi Mold Temperature Controller

REMARKS

 

  • We reserve the right to change specification without prior notice.

STANDARD ACCESSORIES

  • Motor reverse protection

  • Motor overload protector

  • Motor phase shortage protector

  • Overheat protector

  • Compressor overload protector

  • Frost-preventive switch

  • Refrigerant high pressure gauger

  • Refrigerant low pressure gauger 

  • Cooling water pressure gauger

OPTION

Cooling Tower

01

Cooling Tower

  • Unique design and outstanding heat-exhausting effect.

  • Rust prevention.

  • Optional water pump.

FAQ

Mold Temperature Controller

    1. The tooling / mold pipe lines are plugged, cause the pipeline deposit excessive carbon and block the pipe filter.

    2. Improper select wrong mold temperature controller that not meet customer needs.

    3. Lack of flow & electricity.

    4. Find the fault of heating element, contactor, temperature controller.

    1. Find the stuff like as iron filing that stay inside of pipeline to cause the leaking oil.

    2. Improper or over usage this unit standard range.

    1. Check the tank shall have sufficient water. 

    2. Connect correct of cooling water inlet and outlet. 

    3. Check whether plugged of cooler.

    4. Check error of solenoid valve or temperature controller.

    5. Regularly clean or replace the filter.

  • Check the pressure if there is no or insufficient to cause the water flow is short of water outlet to mold.

    1. Happen this condition by mixing with oil and water and then heating. Suggest to replace new kerosene (oil) and clean the pipeline. (Be careful to check the water vapor inside of wheel.

    2. If air left in the pipeline to cause the kerosene emitted and even burned out the heating element.

  • Malfunction of cooling fan, temperature controller, buzzer or indicator light leaking electricity to cause the fuse burned out.

    1. Find no loop or block or lack of kerosene (oil).

    2. Excessive deposition of carbon to cause heating element smoldering. 

    3. Error of EGO (overheat preventer), spot welding death of contactor, malfunction of temperature controller.

  • Molding machine of user is unable in operation, because from the leakage electricity of pump and heating element.

    1. The temperature wave large. (ex. easy to reach 150℃ and down to 130℃)

    2. Inside with vapor. (mixing with oil and water, visual recognition finds the oil muddy or not.)

    3. When find the water inside must be drawn to all of the oil, and then refilled with new oil.

    4. Be attention of heating element when you refilling new oil to prevent the smoldering of heating element.

    5. If your roller machine is high speed rotation about 500 RPM, 20 ~30 RPM per minute will cause the centrifugal and the oil will not be able to fully send out.  Please couple with outside with friction pump to drawn the oil from the inlet of mold temperature controller.

Chiller

  • Temperature controller or thermocouple is faulty. Or Temperature controller does not match up with correct thermocouple. (112 matches up with Light Blue wiring of Thermocouple, and 901 matches up with Light Blue or Gray thermocouple. 902 and 902plus match up with Gray thermocouple.)

  • Check if Cooling fan is damaged, Filter net is stocked, Condenser is stocked, there is no cooling water, or the water pressure is not high enough.

  • Cooling is too well to lead Low pressure protector triggered, please turn cooling water less and decrease the radiations (for Air model). Or there is refrigerant leakage inside piping of unit.

    1. Setting temperature is too low to lead huge differences for overheat protector or damaged.
      ( Setting temperature lower than 5℃ )
      Please change temperature to set at 7~8℃, and reset again after temperature is working normal.

    2. Stopped supplying cooling water to unit would lead Evaporator frosted.
      Please defrost it for 24 hours to reuse it.

  • Reason:
    Low temperature of Environment leads unit working better, but sometimes it would lead Low pressure protector triggered.

    Ans.:

    1. Please turn cooling water less. (to make water circulation not so good)

    2. Adjust Low pressure switch lower than 1kg/cm².
      This is because cooling water is low, and it would make it much lower to lead Low pressure protector triggered. 
      ( Especially Environment Temperature is about 12℃ or lower)

    1. Non-stop working for Compressor for a certain period of time.
      (Compressor keeps working because of unable to reach required temperature from its setting.)

    2. There is water inside Compressor. (Piping damaged and lead water going inside compressor.)

    3. High pressure and Low pressure does not stay at stable value inside Rated range.